Battery Charge

Battery charging method(MF Battery)

1. Constant current charging method
1> Measures battery open circuit voltage which discharges.
2> Open circuit voltage and battery marking dosage proper confirms an electric current and time from the below- mentioned table.
3> Connects battery in the constant current charger and starts charging.
4> When the charging time is completed, separates battery from the charger.
State of
Charge
SP.Gr OCV ~30Ah ~40Ah ~50Ah ~60Ah ~70Ah ~80Ah ~90Ah ~100Ah
1.5A 2.0A 2.5A 3.0A 3.5A 4.0A 4.5A 5.0A
100% 1.265 12.7
75% 1.225 12.4 6Hrs
50% 1.190 12.2 12Hrs
25% 1.155 12.0 18Hrs
Discharged 1.120 11.9 24Hrs
2. Constant voltage charging method
1> Connects battery where discharges to the constant voltage charger.
2> According to the product with lower part for 24 hours charges at same voltage.
12V MF Battery : 16V
12V AGM Battery : 14.4V
3. Consideration fact
1> which is strange from the gas issue will be born or the case where the electrolyte will come out flowing, puts out the charger, inquires wishes in the selling agent.
2> In order for the electrolyte which comes out flowing not to ask in the cloth or the body.
3> If, the electrolyte which comes out flowing and get into skin or eyes, please wash it out . If it got it a lot please contact the doctor.